8/14/02
43
SYSTEM VOLTAGE
Fault Reported Possible Cause Action
Battery voltage low fault
Wiring/ Stator/ Regulator/
Battery
Check battery voltage at battery;
minimum voltage 12.8v.
Disconnect ECU and go to Test 1.
Battery voltage high fault Regulator
Ensure regulator output voltage is within
specified range.
Pinpoint Tests
Test Result Action
1. Check wire and terminal
integrity:
- P2 E1
OK Go to Test 2.
Faulty Correct and go to Test 3.
2. With ignition ‘on,’ check
voltage at:
- P2 E1
Same as battery voltage Go to Test 3.
Less than battery voltage
Locate and correct wiring fault; go to Test
3.
3. Run engine check for
presence of fault.
OK Done
Fault still present Contact Cannondale Dealer Service.