Electrical_EFI Service Manual.fm
COOLING FAN (ATV ONLY)
Fault Possible Cause Action
Cooling fan short fault,
Cooling fan open fault
Damaged cooling fan or
ECU, harness short circuit,
fan connector disconnected or
damaged
Component test the cooling fan. Refer to
"Cooling Fan (ATV Only)" starting on
page 46.
Component test the coolant sensor.
Refer to "Coolant Sensor" starting on
page 53.
Check that cooling fan harness connector
is secure.
Verify good main fuse.
Disconnect ECU and go to Test 1.
Pinpoint Tests
Test Result Action
1. Check wire and terminal
integrity:
- P2 G1, P2 G2
OK Disconnect cooling fan and go to Test 2.
Faulty
Locate and correct wiring fault and go to
Test 5.
2. Check wire for short circuit:
- P2 G1 to ground
- P2 G2 to ground
OK Go to Test 3.
Short circuit
Locate and correct wire fault and go to
Test 5.
3. Check wire continuity
between:
- P2 G1 and CN22 pin B
OK Go to Test 4.
Open circuit Correct wiring fault, go to Test 5.
4. Verify 12V(+) at CN22 pin A
OK Go to Test 5.
None
Locate and correct wiring fault, go to Test
6.
5. Reconnect the cooling fan
and ECU and verify proper fan
operation (on at 85°C, off at
80°C coolant temperature).
Verify correct airflow.
OK Done
Faulty Replace ECU and go to Test 7.
7. Run engine and check for
presence of fault.
OK Done
Fault still present Contact Cannondale Dealer Service.